When a fire breaks out, there is a need for instant and centralized actions to prevent a negative situation. For this, as well as preventive measures, a control-receiver for automatic control of fire extinguishing equipment and S2000-ASPT annunciators was developed.

Block assignment

The control control device has the ability to prevent the spread of open fire in a certain area of \u200b\u200bthe premises, into which fire extinguishing materials will be supplied with equal frequency or all at the same time. In automatic or remote mode, it controls a fire extinguishing device that uses powder, gas or aerosol.

fire extinguishing system at the enterprise
fire extinguishing system at the enterprise

According to the instructions, ASPT S2000 has the ability to receive instructions and transmit alarm information to network controllers of such types as S2000 and S2000M or the Orion complex. The unit receives and processes information signals from detectors that can operate in an independent, manual or active type of power supply. Carries out management activities for working with annunciators based on light and sound capabilities. Assumes control over the engineering equipment of the premises, including ventilation. S2000-ASPT monitors the operability of the automatic fire extinguishing system, monitors all types of annunciators, receives information from door sensors and pressure alarm devices.

System Capabilities

The automatic fire extinguishing system has a built-in function to transmit information such as fire and malfunction to the fire extinguishing control panels. Used as an addressable block in the Orion co-integrated mode. To increase the starting chain directions, it is used with the S2000-KPB system. The S2000-ASPT device operates in the field of fire alarms with an autonomous or centralized mode of protecting buildings from fires.

Repairable, serviceable, reusable, monitorable, and multifunctional.

block aspt s2000
block aspt s2000

This system is powered by two options:

  1. The main source is AC 220 V, 50 Hz.
  2. Two 12 V batteries in series can be used as an alternative power source.

The operating instructions for the S2000-ASPT indicate that the system has the ability to work around the clockmode. The device is not recommended for use when exposed to aggressive environments.

Technical parameters

The S2000 fire extinguishing system covers one open fire extinguishing zone with its functional resources. Equipped with three alarm loops. In its branching, it contains 8 switched circuits per single fire area.

Together with devices, the S2000-KPB includes in its structure about 97 outputs for activating automatic fire extinguishing installations, without them there is only one output.

Sirens with a light base are controlled by three outputs. At the same time, the board is equipped with characteristic signals "GO OUT / DO NOT ENTER / Automation is disabled". For sound annunciators, there is one output with a "Siren" signal. Engineering equipment, according to instructions S2000-ASPT, has one exit.

automatic system aspt s2000
automatic system aspt s2000

Control circuits received 10 inputs in the design of the system. They include:

  • 3 alarm loops;
  • 1 door chain;
  • 1 manual start sensor sequence;
  • 1 universal pressure switch circuit input;
  • breakdown of the automatic fire extinguishing installation controls the circuit with 1 input;
  • serial linking of electronic ID readers – 1 input;
  • RS-485 shell - 2 inputs.

S2000-ASPT operating temperature ranges from 0 °C to +55 °C. It has overall dimensions of 310x254x85 mm and weighsabout 8 kg.

Operation and safety

For the normal functioning of the entire system, it is necessary to carry out work with the batteries connected and fully charged.

After unpacking the equipment, you should pay attention to the absence of mechanical damage and check the presence of all parts of the kit by visual inspection. Before activating the device, it must be stored in normal conditions for a day.

aspt s2000: instruction
aspt s2000: instruction

During the installation and operation of the device, you should follow the operating instructions for the S2000-ASPT, as well as adhere to the safety measures for working with electrical installations.

Direct installation, inspection, maintenance and other manipulations with the device must be carried out by persons with a permit of the appropriate safety qualification.

Fire extinguishing system connection

Installation connection includes data reconfiguration tasks by connecting a computer to a common line interface. Next is the connection to the S2000-ASPT battery and AC power. Wait until the process of turning on the system is completed. Using specialized software, start scanning devices on the computer, select the found device and run the program for changing configuration parameters by activating the "Write configuration" option.

Also, according to a certain scheme, you need to connect external circuits to the terminals mounted on the device.

connection aspt s2000
connection aspt s2000

Preparing for operation

In order to start working with the S2000-ASPT device, you need to familiarize yourself with the control capabilities, indication signals and technical data of the device in advance. In order to avoid negative consequences of the operation of the device, it is necessary to carry out a verification test for the operability of all components of the system. The necessary actions are described in detail in the instruction manual.

Recommended: