Return valve and its application

Return valve and its application
Return valve and its application
Anonim

The non-return valve is used to give the internal environment the desired direction, and it is the only thing done to exclude the possibility of movement of the existing environment in the opposite direction. This type of reinforcement is presented in several forms. Check valve can be rotary and lifting.

check valve
check valve

For oil storage and water intake devices, a valve with a grid is used, it is also called a receiving valve. Installation of this type of reinforcement is always carried out in a single direction. Increasing the sensitivity of the valve to a change in the flow of the medium is possible due to the fact that the plate is equipped with a weight or spring. However, this can cause loss of pressure, as well as increased energy consumption, which is required to move the internal environment of the pipeline. In some cases, it is obliged to allow the circulation of the coolant in a natural way. In such devices, complete locking occurs with a reverse flow that is higher than the calculated one. However, the circulation in this case does not stop, since there is a smallhole, which takes responsibility for the necessary circulation of the medium inside the pipeline.

Check valve sewerage
Check valve sewerage

Sometimes a non-return valve is applicable as non-return valves. This possibility is realized due to the fact that the device is equipped with a spindle or other element that allows you to press the plate to the saddle, thereby fixing it. Lift valves are much simpler in design than rotary valves, but at the same time they are absolutely identical in reliability and tightness. The disadvantage of this type of devices is that when working in a polluted environment, sometimes the shutter sticks. Lift check valves are used for relatively small passage diameters and clean media. In other cases, it makes sense to use the rotary type.

The ventilation check valve is designed to automatically close the cross section of the duct in automatic mode when the fan is turned off. The principle of operation of these devices is gravitational. The flaps of the valves open under the influence of the air flow, and when its supply is stopped, they return to their original position also in automatic mode. This principle of operation serves as a limitation for the use of this type: in a horizontal section it must be installed with a clear orientation of the “top-bottom” of the device, and in a vertical section it is used only if the flow is directed upwards. It is not customary to impose tightness requirements on this type of fitting.

Check valve ventilation
Check valve ventilation

In other areascheck valve is also applicable. Sewerage uses it to block the movement of flow in the opposite direction in case of clogging of pipes with a variety of drains. Different types of devices are designed for different types of pipes, this allows you to achieve the desired effect in each specific situation.

Produce check valves from different materials. The specific type is selected based on what type of pipe it fits.